Cairo Business Plaza new Cairo Better Home Co.
The project Cairo Business Plaza consists of two buildings
Building A&B
The percentage of buildings is 40% of the land area
On four main streets, the main street, 30 m wide
Side streets with a width of 12 m
The buildings are designed according to requirements
LEED green building certification have met all the requirements
And its implementation in the building, which is an internationally recognized accreditation
The way of thinking and redesigning places to serve the environment
Building components:
Ground floor + 5 floors
The distance between the columns is 8 meters
Ground height of 6 m
Five floors with a height of 4 m
A large inner courtyard to provide lighting to the building from the inside; an interior land scape.
Building Finishing:
The entrances to the building are made of high-quality marble and granite.
– Interior corridors specifications Porcelain floors; gypsum board ceilings.
– There is a central air conditioning system in the building.
There is an industrial ventilation system in the building. FRESH AIR
Interfaces:
– Glass fronts – Marble cladding
Aluminum cladding
Granite floors and walls for the main entrances
The floor of the building contains:
8 elevators; one capacity for 20 people.
12 bathrooms; taking into account the presence of bathrooms for people with special needs according to the requirements.
2 major ladder
1 ladder for services / flight.
2 elevator services.
Places available for public services in the role:
Meeting room. Smoking area.
– Rest area and cafeteria. – External parking spaces for clients.
There are places for charging electric cars in the garage.
– The internal corridors between the units with a width of 3 m
Specifications of units delivery to building: A
The units will be fully finished.
Flooring (Porcelain).
Jotun Paints walls.
Ceilings, gypsum tiles 60 x 60 cm, imported.
Central air conditioning system inside the unit at the exits.
Ceiling lighting units, lighting switches, electrical, telephone and television outlets.
– Sanitary appliances in high-quality bathrooms.
Fire fighting system in addition to the fire alarm system
Unit spaces of building: A
Starting at 56 meters
Building components:
Ground floor + 7 floors
The distance between the columns is 8 meters
Ground height of 6 m
Five floors with a height of 4 m
A large inner courtyard to provide lighting to the building from the inside; an interior land scape.
Building Finishing:
The entrances to the building are made of high-quality marble and granite.
– Interior corridors specifications Porcelain floors; gypsum board ceilings.
– There is a central air conditioning system in the building.
There is an industrial ventilation system in the building. FRESH AIR
Interfaces:
– Glass fronts – Marble cladding
Aluminum cladding – granite floors and walls for the main entrances
Services on each floor of the building:
The floor of the building contains:
4 elevators; capacity of one elevator is 20 people
6 bathrooms; taking into account the presence of bathrooms for people with special needs in accordance with the requirements
Ladder for services / flight.
Elevator services.
Places available for public services in the role:
– Rest area and cafeteria. – External parking spaces for clients.
There are places for charging electric cars in the garage.
– The internal corridors between the units with a width of 3 m
Specifications of units delivery to building: B
Units will be delivered without finishing
– floors and ceilings, concrete, pillars, concrete
– Brick walls
– Drain points – feeding – phone – cold water inlets on top of each unit.
Unit spaces of building: B
Starting at 230 meters
customer service MIDTOWN New Cairo